Home| All soft| Last soft| Your Orders| Customers opinion| Helpdesk| Cart

Program Search:


Shopping Cart:




*Note: Minimum order price: €20
We Recommend:
Graphisoft ArchiCAD 17 plus Cigraph and Add-Ons Build 5005 x64 €55 buy download

Year / Issue Date: 2013
Version: 17 Build 5005
Developer: Graphisoft
Developer website: graphisoft.com
Bit: 64bit
Language: English

System Requirements : Operating System - Windows ® 8 (64- bit ) Windows ® 7 (64- bit ) Windows ® Vista ( 64- bit)
Processor - Requires 64-bit Intel Core2 Duo processor or higher.
Memory - Requires 4 GB of RAM. It is recommended to use an 8 GB or more for complex models .
Hard disk space - for the complete installation program requires a minimum of 5 GB. In addition, to work with complex models and three-dimensional visualization requires about 10 GB.
Graphics Card - Requires a video card that supports OpenGL 2.0 mode with video memory of 256 MB . Recommended video card with 512 MB of VRAM or more.
Monitor - Required resolution : 1024x768. Recommended resolution : 1280x1024 or higher

ArchiCAD 17 - BIM in every detail
Using ArchiCAD, you will discover the benefits of architectural design in 3D- space , and get pleasure from the incredible freedom in their work. Based on deep knowledge of the architectural process , ArchiCAD building information model completely mimics the construction of real buildings. When solving any problems from urban planning and worked to details , from functional studies to complex structures - specialized tools ArchiCAD always available and easy to use, giving you complete creative freedom .
In ArchiCAD, you see created by 3D- model of a building on which automatically generates all the necessary documents and images . The project develops and acquires a life on the screen simultaneously with the work of your thoughts , you can focus on creativity. Building Information Modeling is the most natural and intuitive approach to design and clarity thanks 3D- representation of projects , customers will be impressed with your creativity .
BIM- details
ArchiCAD 17 offers the best solution of all those present in the market today , a process aimed at creating a working document on the basis of BIM. These solutions significantly simplify the process of modeling and creating drawings , even at a very high level of detail of the project. Implemented in ArchiCAD through the process of working with the building information model allows to use it at all design stages . Support for new technologies is using Building materials having priority compounds requisites display and physical properties , as well as the automatic creation of intersections allow up to a whole new level of project documentation .
3D- design
ArchiCAD 17 includes a large number of innovations and improvements aimed at 3d- design, including large number of parameters and characteristics of the elements created tool MORF ®, recognized in catalogs and specifications , dynamic 3D- Plane sections , giving the possibility of additional control in the simulation 3D- space ArchiCAD. Enabling application BIMx in the installation package allows users to provide their customers with access to projects in an interactive way .
Open BIM
GRAPHISOFT Company continues to develop the direction of Open BIM using best -in-class cross-program interaction for architects and engineers . Using intelligent BIM- processes , errors arising from the interaction between the main CAD, can be reduced to almost zero before the start of the construction phase . ArchiCAD 17 continues to offer BIM- simplification of the process, including through integration with BIMobject.com, as a result of the use of a fully functional application BIMx, and thanks to the fully built LEED- compliant solutions EcoDesigner STAR ™.
energy Efficiency Rating
Improvements were made and sold in ArchiCAD technology Energy Efficiency Ratings , now supporting a plurality of thermal blocks . This allows users to analyze designs in full compliance with applicable standards , and makes the most ekootvetstvennym ArchiCAD BIM- solution of all available on the market today .
performance
ArchiCAD 17 includes revolutionary solutions based on the use of multi-threaded computing and to improve the processing speed to create large models. Advanced technology background processing provides quick generation of parts of any complexity. Optimized use of multicore processors provides significant performance gains when working with complex models . Improved Main graphics core that can achieve a smoother 3D- navigation when working with models of all sizes.

NEW:
List of bugs fixed in this Hotfix
162393 DOCUMENT: Full layouts and sections of particular projects could become rotated.
164080 DOCUMENT: If in the Work Environment the User Preference Schemes -> More Options -> Do not launch new instance of ArchiCAD when placing a view onto Layout setting was checked, drawings could not be placed, only an empty frame appeared.
165550 DOCUMENT: Interactive Schedule didn't show the Integer value list properly.
160250 DOCUMENT: mulitplane roof pitch was not listed properly.
143997 DOCUMENT: Particular symbol fill could cause large PDF file.
158237 DOCUMENT: PDF saved on Windows and opened in Preview on a MAC (or placed into ArchiCad) rendered unreadable text with faulty tracking.
166656 DOCUMENT: Rendered image could be black in Lightworks, if 3D Cutaway blocked Sun and Sky objects.
159404 DOCUMENT: Reviewer did notwork with newer Java applets.
159411 DOCUMENT: Some Master Layouts hid Elements with New Renovation Status.
148152 DOCUMENT: When listing objects in Interactive Schedule there was no criteria referring the Zone that they were placed in.
158118 DOCUMENT: Zones which were overridden by renovation and MVO lost their renovation override style in the saved and printed pdf.
163334 EDIT: Align Texture was working erroneously with curved and slanted beams.
163331 EDIT: Aling Texture's Set Origin worked erroneously on curved walls.
158581 EDIT: Changed IFC properties weren't kept when saving a Favorite from the Element.
161572 EDIT: After copy-pasting Story-linked elements to the upmost story, they loose their linked status.
161862 EDIT: Crash could occur when adjusting Editing plane.
165558 EDIT: Editing a mesh could cause crash.
165270 EDIT: First floor could not be selected as scheduling criteria in the following language versions: CZE, CHI, JPN, NOR, RUS, USA
164347 EDIT: Force Guide Line command didn't work with the Door, Window tools.
161123, 162933 EDIT: If a parameter of an object was changed in section or elevation view, when switched to another section/elevation view the object would not be updated.
160818 EDIT: If Resize command was used repeatedly to modify an element, Resize ratio values once set were not retained in the element's pop-up window.
164149 EDIT: If you mirror a fill with the Area text display on then after editing the mirrored fill the area text got dispositioned.
163894 EDIT: In section selecting and changing grouped elements did not have an effect on the invisible elements.
165052 EDIT: Placing Doors and Windows Using Special Snap Constraint went wrong when guide line was active.
162129 EDIT: Position of a traced detail on another detail view could be inconsistent.
157406 EDIT: Status of zones with geometry method changed from "Manual" to "Inner Edge" were incorrect and they couldn't be updated.
160927 EDIT: Surface renovation override did not work for Morph.
163783 EDIT: Updating zones could cause crash in certain situations.
160814 EDIT: When heights of hotspots of mesh were edited one after the other the last used command were not retained by Pet Palette.
160310, 163982 EDIT: Windows with Custom Corner and Corner Windows were not placed where the first feedback showed.
163889 EDIT: Could not paste rich text or figure into ArchiCAD.
159768 ENERGY EVALUATION: Central Boiler Unmet Load Hours was erroneously calculated under certain circumstances.
161508 ENERGY EVALUATION: Cooling's and Ventilation's auxiliary system data were missing from Report.xls.
160025 ENERGY EVALUATION: Default system characteristics of a new cooling machine were wrong.
165033 ENERGY EVALUATION: Discrepancy could appear in solar radiation percentage of openings.
165218 ENERGY EVALUATION: Energy Evaluation calculation didn't finish and an error message appeared.
160923 ENERGY EVALUATION: In particular files sewage calculation was wrong if Local Heat Pump was used for Service Hot Water Generation.
162053 ENERGY EVALUATION: Service Hot Water Heating and Sewage didn't appear on the Energy Balance in certain circumstances.
159888 ENERGY EVALUATION: Setting BoilerSystem -> Heat Loss value could cause erroneous efects on the simulation result.
165258 ENERGY EVALUATION: Solar absorptance unit was missing in case of Tree View
166044 ENERGY EVALUATION: Switching between radio buttons on the Climate Data dialog could crash ArchiCAD.
161037 ENERGY EVALUATION: The Cooling quantity in the report didn't match with the quantity in the xls.
161507 ENERGY EVALUATION: The Target of the Renewable Energy Source was missing from the 2nd and 3rd bar charts of the Report.PDF's Energy Consumption by Sources chapter, if Heat Pump or Solar collector is used for heating.
163880 ENERGY EVALUATION: Warning message could appear in Energy evaluation because some polygons weren't segmented.
161509 ENERGY EVALUATION: With particular file Auxiliary Electricity appears on Report.pdf if District Cooling was used.
160058 ENERGY EVALUATION: With particular file Central Cooling Machine was unable to meet cooling demand, even with maximum capacity.
161589 ENERGY EVALUATION: With particular file Cooling Energy Quantity was wrong in the Energy Consumption chapters of the Report.pdf.
160922 ENERGY EVALUATION: With particular file Energy Consumption calculation of Heat Pumps used for Service Hot Water Heating was wrong.
161454 ENERGY EVALUATION: With particular file Energy source and target quantities were wrong on Report.pdf if cooling machine was used.
161465 ENERGY EVALUATION: With particular file Peak Cooling data was wrong on Report.pdf if cooling machine was used.
161489 ENERGY EVALUATION: With particular file Primary Energy calculation of heat pump for heating was wrong.
160944 ENERGY EVALUATION: With particular file Sewage calculation was wrong if Central Heat Pump was used for Service Hot Water Generation.
162001 ENERGY EVALUATION: With particular file Solar Collector Type setting had no effect on calculation.
163905 FILE/DWG/EXPORT/ÖNORM: Only attributes with values were exported to DWG.
163928 FILE/DWG/EXPORT/ÖNORM: Text settings of zones' text blocks were lost.
163191 FILE/DWG/EXPORT: A specific combination of template and translator settings caused DWG export to resulte in a 0kb faulty DWG file.
165560 FILE/DWG/IMPORT: Relinking, opening DWG could cause crash.
159637 FILE/EXPORT/PDF: Trace Reference wasn't exported to PDF if Rotated Orientation was set and there were Elements far from Origin.
164938 FILE/EXPORT/SKETCHUP: Usage of national characters in the add-ons directory resulted in the export of a 0 kb sketchup file.
164496 FILE/IFC: Improved export and import of large models.
159569 FILE/IFC/EXPORT: Element quantities can be exported into custom properties.
162596 FILE/IFC/EXPORT: IFC Quantities 'GrossFloorArea' and 'NetFloorArea' were switched upon IFC export.
143209 FILE/IFC/EXPORT: Openings with slanted reveal might look incorrect in IFC.
161549 FILE/IFC/EXPORT: Warning message that "Some elements could not be exported due to missing geometry" appeared after exporting empty openings.
163271 FILE/IFC/IMPORT: After importing a particular IFC file 2D symbol of doors were missing and viewing their settings brought up error message.
165612 FILE/IFC/IMPORT: If the column settings in the default template had a veneer, IFC imported columns would inherit this veneer.
147046 FILE/IFC/IMPORT: Wall niche became an opening when imported into ArchiCAD.
161699 FILE/MIGRATION: After migrating a file containing elements very far from the origin the coordinates of elements could double.
165203 FREEZE: A mouse clicked in certain regions close to a spline could make ArchiCAD unresponsive.
163057 FREEZE: Non-responsive behaviour occurred when background processing of 3d elements refused to allow user interaction.
160731 FREEZE: On Mac ArchiCAD seemed to be freezing due to the fact that the publishing window came back behind the main ArchiCAD window after switching between applications.
163391 GDL: CALL function couldn't be rebuild, when it was used for macro name.
163963 HOTLINK: Hotlink update did not work with particular file.
161479 HOTLINK: In the Host file Hotlinked Zones weren't scheduled properly. Several Zone parameters appeared to be 0 instead of the real value.
161045 HOTLINK/LIBRARY HANDLING: Deleted or broken Hotlink's Embedded library couldn't be removed from the Host file.
163791 INSTALL: Hotfix or additional installations could only be made by the same user who had installed ArchiCAD because limted permission of the newly created folders.
163409 MODEL: After deleting a wall and then undoing the operation the original intersection geometry with a roof was not restored.
157576 MODEL: Align 3D command didn't work on polygonal Walls.
161498 MODEL: Align 3D Texture commands had no effect on Beams.
162032 MODEL: Checking and correcting code was added to better handle 3D junction data.
161832 MODEL: Curved beams didn't cut walls.
163209 MODEL: Sun and sky objects did not work with marquee.
165856 MODEL: textures with alpha channel appeared incorrectly with black patches on OS X 10.9 Mavericks.
165619 MODEL: When a Wall-end was placed with a height parameter lower then the floor cut plane, window related error message erroneously appeared.
156754 SPEED: Slowdown or freeze could happen while having multiple ArchiCAD instances running side by side.
164880 TEAMWORK: Changing Elevation Dimension' level wasn't send to the server, thus different teammates could see different Dimensions.
165880 TEAMWORK: In special cases level dimensions could be sources of Teamwork join errors
159171 TEAMWORK: Project backups created with previous versions could not be imported in BIM Server Manager
161576 TEAMWORK: There were GDL elements that could make a file sharable, but not joinable.
162760 TEAMWORK/EDIT: Composites could be edited while not reserved in TW.
160546 TEAMWORK/FREEZE: If many people were active in a teamwork project, one viewer of an Interactive Schedules could experience erratic scrolling and/or non-responsive behavior.
156759 USER INTERFACE: Navigating in 2D using 3Dconnexion Space Navigator worked in wrong direction.
165663 USER INTERFACE: When using ArchiCAD on two displays palettes with left side title bar could get inaccessible on MAC OS X 10.9 after dragging them to the border area between two displays.

FAILURE
Issue
In Section/Elevation changing Renovation Status of elements or using Edit Selection Set tool crashes ArchiCAD.
Cause
Programming error.



Download File Size:2.51 GB


Graphisoft ArchiCAD 17 plus Cigraph and Add-Ons Build 5005 x64
€55
Customers who bought this program also bought:
  • Abvent Artlantis Studio 5.1.2.2 Multilingual x64 €28
  • Corel Draw Graphics Suite X3 13.0 €40
  • Adobe Illustrator CS6 16.0.1 Multilingual €60
  • V-Ray 2.40.03 for 3ds Max 2009-2013 €25
  • Digital Tutors Site Design and Modeling in Revit €15
  • Digital Tutors Conceptual Massing in Revit €15
  • Autodesk Inventor Pro 2015 x64 (1 dvd) €85
  • Apprendre ArchiCAD 17 La premiere formation en tutoriel video Video €1
  • Autodesk Product Design Suite Ultimate 2015 €250
  • Autodesk Factory Design Suite Ultimate 2015 x64 €198

  • Home| All Programs| Today added Progs| Your Orders| Helpdesk| Shopping cart      





    AutoCAD 2023 €110


    SolidWorks 2022 €115


    AutoCAD 2023 for Mac €110






    Intuit QuickBooks Enterprise Solutions 2021 €40


    Mindjet MindManager 2022 €22


    Chief Architect Premier X13 €50






    DxO PhotoLab 5 ELITE €25


    SketchUp Pro 2022 €30


    Corel Painter 2023 €40